Septic Tank Size Estimator

Enter how many people use the tank, get its size. E.g. 8 users need a 2.0×0.9×1.0 m (1,800 litre) tank.

How many people use the tank daily — include family plus tenants if any

Recommended tank size

2 × 0.9 × 1 m

Users
6 people
Liquid volume
1,800 litres
Volume (in cft)
63.6 cft
Size — L × W × depth (metres)
2 × 0.9 × 1 m
Size — L × W × depth (feet)
6.6 × 3 × 3.3 ft
Chambers
1 chamber
Freeboard (empty above liquid)
0.3 m

For 6 people, build a 2 × 0.9 × 1 m (1,800 litres litre) tank — 1 chamber.

Based on IS 2470 (Indian) standard — confirm with a mason/engineer; soil and water table matter.

How this was calculated
  1. From table: for 6 people, the up-to-10 people row — 2 × 0.9 × 1 m = 1,800 litres litres
  2. Cft = 1,800 litres ÷ 28.3168 = 63.6 cft
  3. Volume is within 2,000 litres — 1 chamber is enough
  4. Keep 0.3 m freeboard above the liquid (total depth = liquid + freeboard)

How to use

  1. Enter how many people use the tank daily (include family plus tenants if any).
  2. The result shows length, width, depth, litres, cft and the number of chambers.
  3. Above 20 users the volume comes from a formula — get dimensions from an engineer.

Size table (IS 2470)

Standard sizes by users — length × width × liquid depth (metres)

Users Size (m) Litres Cft Chambers
Up to 5 1.5 × 0.75 × 1.0 1,125 39.7 1
Up to 10 2.0 × 0.9 × 1.0 1,800 63.6 1
Up to 15 2.0 × 0.9 × 1.3 2,340 82.6 2
Up to 20 2.3 × 1.1 × 1.3 3,289 116.2 2
  • Keep 0.3 m freeboard (empty space) above the liquid — total depth = liquid depth + 0.3 m.
  • Above 20 users, work out the volume with the formula below and get dimensions from an engineer.

Formula

V = P × (C × T + N × S) V = volume (litres), P = users, C = 135 litres/head/day, T = 1 day, N = 2 years, S = 30 litres/head/year sludge. That is 195 litres per person.

Worked example

8 users → the up-to-10 row:

Volume = 1,800 litres = 1,800 ÷ 28.3168 = 63.6 cft. Size = 2.0 × 0.9 × 1.0 m = 6.6 × 3.0 × 3.3 ft. Within 2,000 litres, so 1 chamber is enough, with 0.3 m freeboard on top.

Construction notes

  • Watertight: seal floor and walls — incoming groundwater stops the tank working, leaking sewage pollutes.
  • Vent pipe: always fit a gas vent, or smell and pressure build up.
  • Lid and manhole: keep an openable, sturdy lid for cleaning; no heavy vehicles on top.
  • Soak pit distance: keep it a safe distance from drinking-water tubewells and wells.
Details: where the formula comes from

Two parts: (1) one day’s flow — 135 litres/head × 1 day = 135 litres; (2) two years of sludge — 30 litres/head/year × 2 years = 60 litres. Total per person: 135 + 60 = 195 litres. E.g. 30 users → 30 × 195 = 5,850 litres (≈ 206.6 cft).

The small table rows are roomier than the bare formula — they honour the minimum 1,000 litres, minimum 0.75 m width and minimum 1.0 m liquid depth.

Frequently asked questions

How often should a septic tank be cleaned?

Usually every 2–3 years the settled sludge must be pumped out. Bad smell, overflowing water or slow-flushing toilets mean the tank is full — get a vacuum tanker without delay.

What is a soak pit, and when is it needed?

A soak pit is a gravel-and-sand-filled pit after the septic tank where the treated liquid soaks into the soil. Where the water table is high it does not work well — take an engineer's advice there.

When is a two-chamber tank needed?

Above 2,000 litres, build two chambers — the first about twice the second. Two chambers settle solids better and clog the soak pit less.

What size tank for a family of 5?

The IS 2470 up-to-5 row: 1.5×0.75×1.0 m liquid depth, 1,125 litres — one chamber is enough. For 6–10 users take the 2.0×0.9×1.0 m (1,800 litre) row.

What about high water table or sandy soil?

A high water table can float an empty tank or push water in, and sandy soil fills soak pits fast. Build fully watertight, reduce depth in favour of length, and always consult a mason or engineer.

Also searched as

septic tank size calculation · septic tank dimensions · soak pit size · septic tank size for 10 persons