Column Steel Calculator

Enter the column size and bars. A 10 ft column with 4×20 mm + 4×16 mm bars and 10 mm stirrups at 6″ takes ≈ 71.42 kg (with 10%).

ft

Main bars group 1

Diameter (mm)

Main bars group 2 (optional)

Diameter (mm)

Keep 0 when there is no group 2

Column size (inches)

in
in

Stirrups

Stirrup diameter
Stirrup spacing

Usually 4–8 in

in

Usually 1.5 in for columns

%

Usually 10% with floor-joint laps

৳

Total steel (with wastage)

71.43 kg

Main bars
49.31 kg
Stirrup count
21
Each stirrup
3.96 ft
Stirrup weight
15.62 kg
Net weight
64.93 kg
In tons
0.071 t

This column needs about 71.43 kg of steel.

How this was calculated
  1. Main bars = Σ(count × dia² ÷ 162.2) × height (m) = 49.31 kg.
  2. Stirrups = height ÷ spacing + 1 = (10 × 12) ÷ 6 + 1 = 21.
  3. Cutting length = 2 × core perimeter + hooks − bends = 2 × ((12 − 2 × 1.5) + (15 − 2 × 1.5)) + hooks − bends = 3.959 ft.
  4. Stirrup weight = 21 × 3.959 ft × 0.6165 kg/m = 15.62 kg.
  5. With 10% wastage: 64.93 + 10% = buy 71.43 kg.

How to use

  1. Enter the column height in feet and its size in inches.
  2. Give each main-bar diameter and count (keep 0 when there is no second group).
  3. Pick the stirrup diameter and spacing; keep 10% wastage with laps.

Column steel formulas

Part Formula Example (10 ft, 4×20 + 4×16, 12″×15″)
Main bars Σ(count × dia² ÷ 162.2) × height (m) 16.176 × 3.048 = ≈ 49.30 kg
Stirrup count height ÷ spacing + 1 120 ÷ 6 + 1 = 21
Cutting length 2 × core perimeter + hooks − bends ≈ 3.96 ft each
Stirrup weight count × length × dia² ÷ 162.2 21 × 3.96 × 0.617 = ≈ 15.62 kg
Total (main + stirrups) + wastage% with 10%: ≈ 71.42 kg

Examples

10 ft column (12″×15″): 4×20 mm + 4×16 mm main ≈ 49.30 kg; 10 mm stirrups at 6″: 21 × 3.96 ft ≈ 15.62 kg; net ≈ 64.92 kg, ≈ 71.42 kg with 10%.

Six 16 mm main bars only: same column — main = 6 × 256 ÷ 162.2 × 3.048 ≈ 28.86 kg; net with stirrups ≈ 44.48 kg.

What to know in Bangladesh

  • Stirrups hold the column together: main bars carry load while stirrups tie them and resist shear — count both.
  • Spacing is usually 4–8″: follow the drawing; base and top often get denser stirrups.
  • Bar groups: big columns mix two main sizes (e.g. 20 + 16 mm) — enter both groups separately.
  • Counts come from design: bar numbers and spacing are the engineer’s drawing; this is only the weight.
More: hooks and bends

Two 135° hook ends add 2 × 10 × diameter; three 90° bends deduct 3 × 2 × diameter. For 10 mm stirrups that is ≈ 7.87″ of hooks minus ≈ 2.36″ of bends.

Core perimeter = (width − 2 × cover) + (depth − 2 × cover); cover is usually 1.5″.

Frequently asked questions

What is the main-bar formula?

Σ(count × dia² ÷ 162.2) × height (m). Four 20 mm + four 16 mm bars over 10 ft: (4 × 400 + 4 × 256) ÷ 162.2 × 3.048 ≈ 49.30 kg.

How is the stirrup count found?

Height ÷ spacing + 1. At 6″ over 10 ft: 120 ÷ 6 + 1 = 21.

How long is one stirrup?

Cutting length = 2 × core perimeter + hooks − bends. About 3.96 ft for a 12″×15″ column with 1.5″ cover and 10 mm stirrups.

Where is lapping?

Extra bar for joining main rods at floor joints rides inside wastage (10% is usual for columns).

How many bars does a column need?

The engineer decides from loads and size — usually 4–8 main bars. This calculator weighs bars; it doesn't design them.

Also searched as

column reinforcement estimate · stirrup count formula · column rod weight bd